C•CURE 9000 TAB Article ID: SWH-TAB-000027942 Version: 2.80 Published: Sep-29-2020 BACKGROUND After upgrading C•CURE 9000 to version 2.80, sites have reported several instances where limited operator privileges no longer function correctly. Users with System All privileges are unaffected. In a victor Unified system the limited operator privileges and victor roles are both used to determine access.… Continue reading After 2.80 Upgrade, victor Temporary Licensing can Affect C•CURE Privileges
Month: September 2020
Creating or Changing the Encryption Passphrase in C•CURE
C•CURE 9000 TAB Article ID: SWH-TAB-000027898 Version: 2.80, 2.90 Published: Sep-11-2020 BACKGROUND If the person installing C•CURE 2.90 chooses to postpone the creation of the Encryption Passphrase, they will need to create one in order to save iSTAR controllers. If there is no passphrase, when attempting to save a controller configuration you will receive… Continue reading Creating or Changing the Encryption Passphrase in C•CURE
Journal Replay Custom Range not Displaying End Date/Time
C•CURE 9000 TAB Article ID: SWH-TAB-000027897 Version: 2.70 SP4, SP5 Published: Sep-11-2020 BACKGROUND SPAR 660660: In 2.70 SP4 and SP5, there is an issue with running a Journal replay. The Journal replay does not show Start and End Date/Times, only the Start Date/Time. SOLUTION This issue is addressed in 2.70 SP5 CU01. Workaround… Continue reading Journal Replay Custom Range not Displaying End Date/Time
2.2.0 HA Software and C•CURE Compatibility
C•CURE 9000 TAB Article ID: SWH-TAB-000027892 Version: HA 2.2.0 Published: Sep-10-2020 BACKGROUND Software House / Innometriks have discovered a compatibility issue between the version of C•CURE running and different HA Services builds (Enrollment Service / Panel Service). When C•CURE 2.70 SP 5 is loaded, the version of ManagedOpenSsl gets upgraded to a newer version than… Continue reading 2.2.0 HA Software and C•CURE Compatibility
2.80 C•CURE Enforces TLS 1.2 Encryption
C•CURE 9000 TAB Article ID: SWH-TAB-000027888Version: 2.80 / 6.2.1Published: Sep-09-2020 BACKGROUND As a response to the increasingly demanding cybersecurity standards, C•CURE version 2.80 enforces encrypted iStar devices to communicate using TLS 1.2 protocol standards. Following this mandate, iStar Edge controllers must run firmware version 6.2.1 or higher to support the protocol. It is very important… Continue reading 2.80 C•CURE Enforces TLS 1.2 Encryption
SQL Permissions for Installing Innometriks HA Services on the C•CURE Server
Innometriks TAB Article ID: SWH-TAB-000027887 Published: Sep-09-2020 BACKGROUND When installing the Innometriks High Assurance integration on the C•CURE 9000 server, creating the database objects in SQL will fail if the proper permissions in SQL Server are not given to the NT AUTHORITY\SYSTEM login account, when selecting Windows Authentication. This issue is being addressed. SOLUTION… Continue reading SQL Permissions for Installing Innometriks HA Services on the C•CURE Server