victor Web Service Fails to Start When Upgrading to 2.90 (Before SP3)

C•CURE 9000 TAB Article ID: SWH-TAB-nID-000006808Version: 2.90, 2.90 SP1, 2.90 SP2Published: Sep-29-2021     Issue Statement C•CURE 2.80 (before SP7) fails cybersecurity vulnerability scans because of the files Microsoft.Data.OData.dll and Microsoft.Data.Edm.dll which are directly related to the victor Web Service (vWS). When installing 2.80 SP7, the offending files are replaced with newer versions. If the… Continue reading victor Web Service Fails to Start When Upgrading to 2.90 (Before SP3)

AD300 Readers Wired to an iSTAR Ultra Have a Different Pinout than iSTAR Pro

Article ID: SWH-KB-nID-000006792Applies To: C•CURE 9000 (General)Published: Sep-22-2021     The AD300 is a hardwired device and therefore has no wireless PIM.  The lock, reader, DC and REX are all built into the device and wired to the iSTAR GCM board, directly.   WIRING Use 485 (twisted shielded wire) from COM Port on the GCM to the AD300.… Continue reading AD300 Readers Wired to an iSTAR Ultra Have a Different Pinout than iSTAR Pro

Client Cannot Connect to Server if System Times Differ by More than 5 Minutes

Article ID: SWH-KB-nID-000006787Applies To: C•CURE 9000 (General) Published: Sep-19-2021     BACKGROUND Both the Administration Workstation and Monitoring Station will fail to connect to the application server if the system time on the client workstation differs by more than 5 minutes from the system time on the application server.     SOLUTION Manually set the… Continue reading Client Cannot Connect to Server if System Times Differ by More than 5 Minutes

Using SQL Transparent Data Encryption (TDE) With C•CURE

Article ID: SWH-KB-nID-000006786Applies To: C•CURE 9000 (General)Published: Sep-19-2021     Microsoft SQL Transparent Data Encryption (TDE) TDE can be configured on SQL Server 2019 Standard, as well as on the Enterprise version of previous SQL servers. As denoted in the name, enabling or disabling TDE on your SQL instance is transparent to C•CURE and how… Continue reading Using SQL Transparent Data Encryption (TDE) With C•CURE

victor Web Service Requires .NET 4.8 When 2.80 SP 6 Is Installed

C•CURE 9000 TAB Article ID: SWH-TAB-nID-000006773Version: 2.80 SP6Published: Sep-01-2021     BACKGROUND  After installing 2.80 Service Pack 6, victor Web Service will not run if .NET 4.8 is not installed on the application server. An error such as this may been seen when attempting to visit the victorwebservice web page: Parser Error Message: The ‘targetFramework’… Continue reading victor Web Service Requires .NET 4.8 When 2.80 SP 6 Is Installed